UV-Vis Spectroscopic Characterization of Nanomaterials in Aqueous Media
Published on: October 25, 2021
Analytical Quality by Design Driven Development and Validation of UV-Visible Spectrophotometric Method for
Harish Vancha1, Devesh Tewari2, Rajesh Kumar1
1Lovely Professional University, School of Pharmaceutical Sciences, Phagwara, Punjab, India.
Objectives:
Xanthohumol (XH) is a prenylated chalcone available naturally and has diverse pharmacological activities. It has some limitations in the physiological environment such as biotransformation and less gastrointestinal tract absorption. To overcome the limitations, we prepared nanoformulations [solid lipid nanoparticles (SLNs)] of XH. Therefore, an analytical method is required for the estimation of XH in the bulk nanoformulations, so we developed and validated a quality by design (QbD)-based ultraviolet (UV)-spectrophotometric method as per the International Conference of Harmonization (ICH) Q2 (R1) guidelines.
Materials And Methods:
The new analytical Qbd based UV-visible spectrophotometric technique is developed and validated for estimation of XH in bulk and SLNs as per ICH guidelines Q2 (R1). Critical method variables are selected on the basis of risk assessment studies. Optimization of method variables was performed using the a central composite design (CCD) model.
Results:
Multiregression ANOVA analysis showed an R2 value of 0.8698, which is nearer to 1, indicating that the model was best fitted. The optimized method by CCD was validated for its linearity, precision, accuracy, repeatability, limit of detection (LOD), limit of quantification (LOQ), and specificity. All validated parameters were found to be within the acceptable limits [% relative standard deviation (RSD) <2]. The method was linear between 2-12 g/mL concentration with R2 value 0.9981. Method was accurate with percent recovery 99.3-100.1%. LOD and LOQ were found to be 0.77 and 2.36 μg/mL, respectively. The precision investigation confirmed that the method was precise with %RSD <2.
Conclusion:
The developed and validated method was applied to estimate XH in bulk and SLNs. The developed method was specific to XH, which was confined by the specificity study.
Related Concept Videos
UV–Vis Spectrometers
Data Validation
Key parameters for method validation include:
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
UV–Vis Spectrum
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar...
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
Qualitative Analysis
There are two main approaches to qualitative analysis:...