Related Experiment Video
Updated: Jul 24, 2025

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
Reliability and time-based efficiency of artificial intelligence-based automatic digital model analysis system
Jae-Hun Yu1,2, Ji-Hoi Kim1,2, Jing Liu1
1Department of Orthodontics, Institute of Craniofacial Deformity, Yonsei University College of Dentistry, Seoul, Korea.
Objectives:
To compare the reliability, reproducibility, and time-based efficiency of automatic digital (AD) and manual digital (MD) model analyses using intraoral scan models.
Material And Methods:
Two examiners analysed 26 intraoral scanner records using MD and AD methods for orthodontic modelling. Tooth size reproducibility was confirmed using a Bland-Altman plot. The Wilcoxon signed-rank test was conducted to compare the model analysis parameters (tooth size, sum of 12-teeth, Bolton analysis, arch width, arch perimeter, arch length discrepancy, and overjet/overbite) for each method, including the time taken for model analysis.
Results:
The MD group exhibited a relatively larger spread of 95% agreement limits when compared with AD group. The standard deviations of repeated tooth measurements were 0.15 mm (MD group) and 0.08 mm (AD group). The mean difference values of the 12-tooth (1.80-2.38 mm) and arch perimeter (1.42-3.23 mm) for AD group was significantly (P < 0.001) larger than that for the MD group. The arch width, Bolton, and overjet/overbite were clinically insignificant. The overall mean time required for the measurements was 8.62 min and 0.56 min for the MD and AD groups, respectively.
Limitations:
Validation results may vary in different clinical cases because our evaluation was limited to mild-to-moderate crowding in the complete dentition.
Conclusions:
Significant differences were observed between AD and MD groups. The AD method demonstrated reproducible analysis in a considerably reduced timeframe, along with a significant difference in measurements compared to the MD method. Therefore, AD analysis should not be interchanged with MD, and vice versa.
More Related Videos
04:57Comparative Analysis of Automatic Fecal Analyzer versus Direct Wet Smear Microscopy for Detecting Parasitic Infections in Stool Samples
Published on: April 25, 2025
06:37Author Spotlight: Addressing Technical and Subjective Challenges in Measuring Classroom Attention
Published on: December 15, 2023
Related Concept Videos
Distribution Reliability and Automation
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...
Simplified Synchronous Machine Model
In this model, each generator is connected to a...
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Stereotype Content Model