Related Experiment Video
Updated: Jul 24, 2025

Author Spotlight: Understanding and Detecting Environmental Antimicrobial Resistance by Combining Culture-Based Techniques and Genomics
Published on: July 19, 2024
Systematic review and meta-analysis of human health-related protein markers for realizing real-time wastewater-based
Luhur Akbar Devianto1, Daisuke Sano2
1Department of Frontier Science for Advanced Environment, Graduate School of Environmental Studies, Tohoku University, Sendai, Miyagi 980-8579, Japan; Department of Environmental Engineering, Faculty of Agriculture Technology, Brawijaya University, Malang 65145, Indonesia.
Abstract:
For effective implementation of the wastewater-based epidemiology (WBE) approach, real-time quantification of markers in wastewater is critical for data acquisition before data interpretation, dissemination, and decision-making. This can be achieved by using biosensor technology, but whether the quantification/detection limits of different types of biosensors comply with the concentration of WBE markers in wastewater is unclear. In the present study, we identified promising protein markers with relatively high concentrations in wastewater samples and analyzed biosensor technologies that are potentially available for real-time WBE. The concentrations of potential protein markers in stool and urine samples were obtained through systematic review and meta-analysis. We examined 231 peer-review papers to collect information regarding potential protein markers that can enable us to achieve real-time monitoring using biosensor technology. Fourteen markers in stool samples were identified at the ng/g level, presumably equivalent to ng/L of wastewater after dilution. Moreover, relatively high average concentrations of fecal inflammatory proteins were observed, e.g., fecal calprotectin, clusterin, and lactoferrin. Fecal calprotectin exhibited the highest average log concentration among the markers identified in stool samples with its mean value being 5.24 [95 % CI: 5.05, 5.42] ng/g. We identified 50 protein markers in urine samples at the ng/mL level. Uromodulin (4.48 [95 % CI: 4.20, 4.76] ng/mL) and plasmin (4.18 [95 % CI: 3.15, 5.21] ng/mL) had the top two highest log concentrations in urine samples. Furthermore, the quantification limit of some electrochemical- and optical-based biosensors was found to be around the femtogram/mL level, which is sufficiently low to detect protein markers in wastewater even after dilution in sewer pipes.

