Related Experiment Video
Updated: Jul 24, 2025

Terahertz Microfluidic Sensing Using a Parallel-plate Waveguide Sensor
Published on: August 30, 2012
Sensitivity-Tunable Terahertz Liquid/Gas Biosensor Based on Surface Plasmon Resonance with Dirac Semimetal
Mengjiao Ren1, Chengpeng Ji1, Xueyan Tang1
1School of Physics and Electronics, Hunan Normal University, Changsha 410081, China.
Abstract:
In this paper, we study the sensitivity-tunable terahertz (THz) liquid/gas biosensor in a coupling prism-three-dimensional Dirac semimetal (3D DSM) multilayer structure. The high sensitivity of the biosensor originates from the sharp reflected peak caused by surface plasmon resonance (SPR) mode. This structure achieves the tunability of sensitivity due to the fact that the reflectance could be modulated by the Fermi energy of 3D DSM. Besides, it is found that the sensitivity curve depends heavily on the structural parameters of 3D DSM. After parameter optimization, we obtained sensitivity over 100°/RIU for liquid biosensor. We believe this simple structure provides a reference idea for realizing high sensitivity and a tunable biosensor device.