Conductor Losses in Radiofrequency Coils for Magnetic Resonance below 3T: Estimation Methods and Minimization

Giulio Giovannetti1, Alessandra Flori2, Francesca Frijia2

  • 1Institute of Clinical Physiology, National Research Council (CNR), Via G. Moruzzi 1, 56124 Pisa, Italy.

PubMed

Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
5.3K
Equivalent Circuits for Practical Transformers01:28

Equivalent Circuits for Practical Transformers

The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
472
Magnetic Field Due To A Thin Straight Wire01:28

Magnetic Field Due To A Thin Straight Wire

Consider an infinitely long straight wire carrying a current I. The magnetic field at point P at a distance a from the origin can be calculated using the Biot-Savart law.
4.9K
Energy Losses in Transformers01:21

Energy Losses in Transformers

In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality,  the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be  the high resistance of the...
907
Imaging Studies for Cardiovascular System IV: CMRI01:21

Imaging Studies for Cardiovascular System IV: CMRI

Cardiovascular magnetic resonance imaging, or CMRI, is a non-invasive diagnostic test that employs a magnetic field and radiofrequency waves to create precise images of the heart and arteries. It provides comprehensive information about cardiac anatomy, function, perfusion, and tissue characterization without ionizing radiation.IndicationsCMRI diagnoses various heart conditions, including tissue damage from heart attacks, ischemic heart disease, myocarditis, aortic issues (tears, aneurysms,...
65
Toroids01:27

Toroids

A toroid is a closely wound donut-shaped coil constructed using a single  conducting wire. In general, it is assumed that a toriod consists of  multiple circular loops perpendicular to its axis.
When connected to a supply, the magnetic field generated in the toroid has field lines circular and concentric to its axis. Conventionally, the direction of this magnetic field is expressed using the right-hand rule. If the fingers of the right hand curl in the current direction, the thumb...
3.0K