Related Experiment Video
Updated: Jul 24, 2025

Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
Investigation of the Temperature Actions of Bridge Cables Based on Long-Term Measurement and the Gradient Boosted
Fen Wang1, Gonglian Dai1, Yonglu Liu2,3
1School of Civil Engineering, Central South University, Changsha 410075, China.
Abstract:
Cable-stayed bridges have been commonly used on high-speed railways. The design, construction, and maintenance of cable-stayed bridges necessitate an accurate assessment of the cable temperature field. However, the temperature fields of cables have not been well established. Therefore, this research aims to investigate the distribution of the temperature field, the time variability of temperatures, and the representative value of temperature actions in stayed cables. A cable segment experiment, spanning over one year, is conducted near the bridge site. Based on the monitoring temperatures and meteorological data, the distribution of the temperature field is studied, and the time variability of cable temperatures is investigated. The findings show that the temperature distribution is generally uniform along the cross-section without a significant temperature gradient, while the amplitudes of the annual cycle variation and daily cycle variation in temperatures are significant. To accurately determine the temperature deformation of a cable, it is necessary to consider both the daily temperature fluctuations and the annual cycle of uniform temperatures. Then, using the gradient boosted regression trees method, the relationship between the cable temperature and multiple environmental variables is explored, and representative cable uniform temperatures for design are obtained by the extreme value analysis. The presented data and results provide a good basis for the operation and maintenance of in-service long-span cable-stayed bridges.
More Related Videos
Related Concept Videos
Cable Subjected to a Distributed Load
Design Example: Strain Gauge Bridge or Wheatstone Bridge
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Cable Subjected to Its Own Weight
A generalized loading function is employed to analyze a cable subjected to its own weight. This function considers the force acting along the cable's arc length rather than its projected length, providing a more accurate...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...