Related Experiment Video
Updated: Jul 24, 2025

A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis
Published on: May 14, 2013
Incidence, risk factors, and clinical sequelae of incomplete stent apposition after sirolimus-eluting stent
Peng Liu1,2, Chun-Guang Qiu2, Zhen-Wen Huang2
11Department of Cardiology, People's Hospital of Hebi, School of Medicine, Henan University, Henan, China.
Incomplete stent apposition has been documented after sirolimus-eluting stent implantation. However, its clinical sequelae remain controversial. To identify the incidence and its clinical consequences of ISA, IVUS was performed on 78 patients. In spite of well apposition immediately after the deployment, late stent malapposition occurred after 6-months follow-up. A total of 7 patients who received SES showed ISA. There were no significant differences in IVUS measurements between patients with or without ISA. However, there was an increase in external elastic membrane area in ISA group than non-ISA group (19.69 ± 3.50 vs. 15.05 ± 2.56 mm2, P<0.05). There were positive clinical events for ISA cases at 6-months clinical follow-up. Univariate and multivariable analyses indicated that hs-CRP, miR-21, and MMP-2 were risk factor for ISA. ISA was observed in 9% of patients after SES implantation, which was related to vessel positive remodeling. The incidence of MACEs in patients with ISA was higher than those without ISA. However, careful long-term follow-up remains to be clarified.
Incomplete stent apposition has been documented after sirolimus-eluting stent implantation. However, its clinical sequelae remain controversial. To identify the incidence and its clinical consequences of ISA, IVUS was performed on 78 patients. In spite of well apposition immediately after the deployment, late stent malapposition occurred after 6-months follow-up. A total of 7 patients who received SES showed ISA. There were no significant differences in IVUS measurements between patients with or without ISA. However, there was an increase in external elastic membrane area in ISA group than non-ISA group (19.69 ± 3.50 vs. 15.05 ± 2.56 mm2, P<0.05). There were positive clinical events for ISA cases at 6-months clinical follow-up. Univariate and multivariable analyses indicated that hs-CRP, miR-21, and MMP-2 were risk factor for ISA. ISA was observed in 9% of patients after SES implantation, which was related to vessel positive remodeling. The incidence of MACEs in patients with ISA was higher than those without ISA. However, careful long-term follow-up remains to be clarified.
Related Concept Videos
Acute Coronary Syndrome II: Pathophysiology and Clinical Manifestations
Mitral Stenosis I: Introduction
Coronary Artery Disease II: Pathophysiology
Aneurysm III: Interprofessional Care
Mitral Stenosis II: Clinical features and Diagnostic Tests
Acute Coronary Syndrome I: Introduction

