Related Experiment Video
Updated: Jul 24, 2025

Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Frequency Of Inappropriate Endotracheal Tube Cuff Pressure And Its Variability In Patients Undergoing Prolonged
Muhammad Fahad Rehman Shamsi1, Ali Sarfraz Siddiqui1
1Department of Anaesthesiology, Aga Khan University Karachi, Pakistan.
Background:
Endotracheal tube (ETT) is inserted into the trachea to maintain airway patency. Maintaining adequate ETT cuff pressure is important to ensure a proper seal to lower the risk of aspiration and tracheal trauma. This study was designed to assess the frequency of inappropriate ETT cuff pressure at the time of intubation and variation in ETT pressure at the end of a prolonged surgery.
Methods:
This study was conducted in the Department of Anaesthesiology, Aga Khan University from October 2019 to March 2020. All adult patients of both genders, undergoing prolonged surgery under general anaesthesia were included. Patients were intubated with an appropriate size ETT, and the cuff was inflated with air. ETT cuff pressure was measured after intubation and, at the end of prolonged surgery to assess any variation.
Results:
Fifty-eight patients were included, of which 37 (63.8%) were female. The mean age was 47.36 years. The frequency of inappropriate ETT cuff pressure at the time of intubation was found in thirty-five (60.3%) patients, which was corrected to 25 cm H2O before the start of surgery. At the end of the surgery, forty-one (70.7%) patients showed an increase in ETT cuff pressures with the majority (33%) having a variation of 51-70 (81-100 cm H2O).
Conclusions:
The frequency of inappropriate ETT cuff pressure at the time of intubation was found in thirty-five (60.3%) patients. In six (10.3%) patients, ETT cuff pressure was below 20 cm H2O while in twenty-nine (50%) patients, ETT cuff pressure was above 30 cm H2O. In forty-one (70.7%) patients ETT cuff pressure was abnormally high that is >30 cm H2O at the end of prolonged surgical procedures.
More Related Videos
05:39Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
04:48Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...