Related Experiment Video
Updated: Jul 24, 2025

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
A Novel Dual Energy Computed Tomography Score Correlates With Postoperative Outcomes in Chronic Thromboembolic
Rahul D Renapurkar1, Jennifer Bullen2, Alain Rizk1
1Section of Thoracic Imaging, Imaging Institute.
Purpose:
To compare dual-energy computed tomography (DECT) based qualitative and quantitative parameters in chronic thromboembolic pulmonary hypertension with various postoperative primary and secondary endpoints.
Materials And Methods:
This was a retrospective analysis of 64 patients with chronic thromboembolic pulmonary hypertension who underwent DECT. First, a clot score was calculated by assigning the following score: pulmonary trunk-5, each main pulmonary artery-4, each lobar-3, each segmental-2, and subsegmental-1 per lobe; the sum total was then calculated. The perfusion defect (PD) score was calculated by assigning 1 point to each segmental PD. The combined score was calculated by adding clot and PD scores. For quantitative evaluation, we calculated perfused blood volume (PBV) (%) of each lung and the sum of both lungs. Primary endpoints included testing association between combined score and total PBV with change in mean pulmonary arterial pressure ([mPAP], change calculated as preop minus postop values). Secondary endpoints included explorative analysis of the correlation between combined score and PBV with change in preoperative and postoperative pulmonary vascular resistance, change in preoperative 6-minute walk distance (6MWD), and immediate postoperative complications such as reperfusion edema, ECMO placement, stroke, death and mechanical ventilation for more than 48 hours, all within 1 month of surgery.
Results:
Higher combined scores were associated with larger decreases in mPAP ( =0.27, P =0.036). On average, the decrease in mPAP (pre mPAP-post mPAP) increased by 2.2 mm Hg (95% CI: -0.6, 5.0) with each 10 unit increase in combined score. The correlation between total PBV and change in mPAP was small and not statistically significant. During an exploratory analysis, higher combined scores were associated with larger increases in 6MWD at 6 months postprocedure ( =0.55, P =0.002).
Conclusion:
Calculation of DECT-based combined score offers potential in the evaluation of hemodynamic response to surgery. This response can also be objectively quantified.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Pulmonary Embolism III: Nursing Management
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Pulmonary Embolism I: Introduction