3.0 T unenhanced Dixon water-fat separation whole-heart coronary magnetic resonance angiography: compressed-sensing
Di Tian1, Yi Sun1, Jia-Jun Guo1
1Department of Radiology, Zhongshan Hospital, Fudan University and Shanghai Institute of Medical Imaging, No. 180 Fenglin Rd, Shanghai, 200032, China.
Abstract:
This study was aimed to investigate 3.0 T unenhanced Dixon water-fat whole-heart CMRA (coronary magnetic resonance angiography) using compressed-sensing sensitivity encoding (CS-SENSE) and conventional sensitivity encoding (SENSE) in vitro and in vivo. The key parameters of CS-SENSE and conventional 1D/2D SENSE were compared in vitro phantom study. In vivo study, fifty patients with suspected coronary artery disease (CAD) completed unenhanced Dixon water-fat whole-heart CMRA at 3.0 T using both CS-SENSE and conventional 2D SENSE methods. We compared mean acquisition time, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and the diagnostic accuracy between two techniques. In vitro study, CS-SENSE achieved better effectiveness between higher SNR/CNR and shorter scan times using the appropriate acceleration factor compared with conventional 2D SENSE. In vivo study, CS-SENSE CMRA had better performance than 2D SENSE in terms of the mean acquisition time, SNR and CNR (7.4 ± 3.2 min vs. 8.3 ± 3.4 min, P = 0.001; SNR: 115.5 ± 35.4 vs. 103.3 ± 32.2; CNR: 101.1 ± 33.2 vs. 90.6 ± 30.1, P < 0.001 for both). The diagnostic accuracy between CS-SENSE and 2D SENSE had no significant difference on a patient-based analysis (sensitivity: 97.3% vs. 91.9%; specificity: 76.9% vs. 61.5%; accuracy: 92.0% vs. 84.0%; P > 0.05 for each). Unenhanced CS-SENSE Dixon water-fat separation whole-heart CMRA at 3.0 T can improve the SNR and CNR, shorten the acquisition time while providing equally satisfactory image quality and diagnostic accuracy compared with 2D SENSE CMRA.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Magnetic Resonance Imaging