Related Experiment Video
Updated: Jul 24, 2025

Digital Hybrid Model Preparation for Virtual Planning of Reconstructive Dentoalveolar Surgical Procedures
Published on: August 5, 2021
Virtual Three-Dimensional Model Analysis in the Assessment of the Maxillary and Mandibular Donor Sites on Cone-Beam
Seyed Moein Diarjani1, Safa Motevasseli2, Zahra Dalili Kajan3
1Department of Maxillofacial Surgery, School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran.
Abstract:
Using the Mimics software to assess the maxillary and mandibular donor sites on cone-beam computed tomography (CBCT) images. This cross-sectional study was conducted on 80 CBCT scans. Data in DICOM format were transferred to the Mimics software version 21, and a maxillary and a mandibular mask according to cortical and cancellous bones were virtually created for each patient based on Hounsfield units (HUs). Three-dimensional models were reconstructed, and boundaries of donor sites, including mandibular symphysis, ramus, coronoid process, zygomatic buttress, and maxillary tuberosity, were defined. Virtual osteotomy was conducted on the 3D models to harvest bone. The volume, thickness, width, and length of harvestable bone from each site were quantified by the software. Data were analyzed by independent t-test, one-way ANOVA, and Tukey's test (alpha = 0.05). The greatest harvestable bone volume and length differences were observed between ramus and tuberosity (P < 0.001). The maximum and minimum harvestable bone volumes were found in symphysis (1753.54 mm3) and tuberosity (84.99 mm3). The greatest difference in width and thickness was noted between the coronoid process and tuberosity (P < 0.001) and symphysis and buttress (P < 0.001), respectively. Harvestable bone volume from tuberosity, length, width, volume from symphysis, and volume and thickness from the coronoid process was significantly greater in males (P < 0.05). The harvestable bone volume was the highest in symphysis, followed by ramus, coronoid, buttress, and tuberosity. The harvestable bone length and width were the highest in the symphysis and coronoid process, respectively. Maximum harvestable bone thickness was found in symphysis.
More Related Videos
05:49Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023