Related Experiment Video
Updated: Jul 24, 2025

Determining Viral Disinfection Efficacy of Hot Water Laundering
Published on: June 21, 2022
Sterilization efficacy of a new water-free breast milk pasteurizer
Mina Chishiki1, Kyoko Nishiyama2, Tatsuo Suzutani2
1Department of Pediatrics, Fukushima Medical University School of Medicine, Fukushima, Japan.
Background:
Breast milk, nature's optimum source of nutrition for infants, can contain undesirable microorganisms that cause severe morbidity. After an outbreak of multidrug-resistant Escherichia coli among neonates receiving breast milk donated by another mother in our neonatal intensive care unit (NICU), we were motivated to develop a high-grade breast milk pasteurizer (BMP) designed to thaw and pasteurize breast milk at 63°C for 30 min in a sealed bag without having to open the bag or immerse it in water.
Methods:
Pre-existing bacteria and spiked cytomegalovirus (CMV) were measured pre- and post-pasteurization in frozen breast milk donated by mothers of children admitted to the NICU.
Results:
Among 48 breast milk samples (mean ± standard deviation [SD]), pre-existing bacterial counts of 5.1±1.1 × 104 colony forming units (cfu)/mL decreased to less than 10 cfu/mL (below detection level) in 45 samples after pasteurization for 30 min. In three samples, 10-110 cfu/mL persisted. As no CMV was detected in any of the 48 samples, CMV at ≥5 × 104 pfu/mL was spiked into 11 breast milk samples. After just 10 min of pasteurization, infectious CMV was not detected (threshold <50 pfu/mL) in any sample.
Conclusion:
A new BMP was shown to pasteurize milk effectively with more than a 3-log reduction of microorganisms. Compared to conventional pasteurizers, this device reduces the effort involved in pasteurizing breast milk, avoids various contamination risks, and may reduce the risk of infectious disease transmission via breast milk.
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Physical Methods for Controlling Microbial Growth: Temperature
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Antimicrobial Effectiveness