GPU-accelerated calculation of proton microdosimetric spectra as a function of target size, proton energy, and
Joseph M DeCunha1,2, Mark Newpower3, Radhe Mohan1
1Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, United States of America.
Abstract:
Objective.Shortcomings of dose-averaged linear energy transfer (LETD), the quantity which is most commonly used to quantify proton relative biological effectiveness, have long been recognized. Microdosimetric spectra may overcome the limitations of LETDbut are extremely computationally demanding to calculate. A systematic library of lineal energy spectra for monoenergetic protons could enable rapid determination of microdosimetric spectra in a clinical environment. The objective of this work was to calculate and validate such a library of lineal energy spectra.Approach. SuperTrack, a GPU-accelerated CUDA/C++ based application, was developed to superimpose tracks calculated using Geant4 onto targets of interest and to compute microdosimetric spectra. Lineal energy spectra of protons with energies from 0.1 to 100 MeV were determined in spherical targets of diameters from 1 nm to 10μm and in bounding voxels with side lengths of 5μm and 3 mm.Main results.Compared to an analogous Geant4-based application, SuperTrack is up to 3500 times more computationally efficient if each track is resampled 1000 times. Dose spectra of lineal energy and dose-mean lineal energy calculated with SuperTrack were consistent with values published in the literature and with comparison to a Geant4 simulation. Using SuperTrack, we developed the largest known library of proton microdosimetric spectra as a function of primary proton energy, target size, and bounding volume size.Significance. SuperTrack greatly increases the computational efficiency of the calculation of microdosimetric spectra. The elevated lineal energy observed in a 3 mm side length bounding volume suggests that lineal energy spectra determined experimentally or computed in small bounding volumes may not be representative of the lineal energy spectra in voxels of a dose calculation grid. The library of lineal energy spectra calculated in this work could be integrated with a treatment planning system for rapid determination of lineal energy spectra in patient geometries.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
06:40Automated Delivery of Microfabricated Targets for Intense Laser Irradiation Experiments
Published on: January 28, 2021