Related Experiment Video
Updated: Jul 24, 2025

Continuous Instream Monitoring of Nutrients and Sediment in Agricultural Watersheds
Published on: September 26, 2017
On-Site Sensor Calibration Procedure for Quality Assurance of Barometric Process Separation (BaPS) Measurements
Hannah Munz1, Joachim Ingwersen1, Thilo Streck1
1Biogeophysics Section, Institute of Soil Science and Land Evaluation, University of Hohenheim, 70599 Stuttgart, Germany.
Abstract:
Barometric process separation (BaPS) is an automated laboratory system for the simultaneous measurement of microbial respiration and gross nitrification rates in soil samples. To ensure optimal functioning, the sensor system, consisting of a pressure sensor, an O2 sensor, a CO2 concentration sensor, and two temperature probes, must be accurately calibrated. For the regular on-site quality control of the sensors, we developed easy, inexpensive, and flexible calibration procedures. The pressure sensor was calibrated by means of a differential manometer. The O2 and CO2 sensors were simultaneously calibrated through their exposure to a sequence of O2 and CO2 concentrations obtained by sequentially exchanging O2/N2 and CO2/N2 calibration gases. Linear regression models were best suited for describing the recorded calibration data. The accuracy of O2 and CO2 calibration was mainly affected by the accuracy of the utilized gas mixtures. Because the applied measuring method is based on the O2 conductivity of ZrO2, the O2 sensor is particularly susceptible to aging and to consequent signal shifts. Sensor signals were characterized by high temporal stability over the years. Deviations in the calibration parameters affected the measured gross nitrification rate by up to 12.5% and affected the respiration rate by up to 5%. Overall, the proposed calibration procedures are valuable tools for ensuring the quality of BaPS measurements and for promptly identifying sensor malfunctions.
More Related Videos
10:22Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
11:02The Use of an Automated System GreenFeed to Monitor Enteric Methane and Carbon Dioxide Emissions from Ruminant Animals
Published on: September 7, 2015
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Common Leveling Mistakes and Errors
Introduction and Methods of Leveling
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: