Related Experiment Video
Updated: Jul 24, 2025

Measuring Respiratory Function in Mice Using Unrestrained Whole-body Plethysmography
Published on: August 12, 2014
Evaluation of a Respiration Rate Sensor for Recording Tidal Volume in Calves under Field Conditions
Lena Dißmann1, Petra Reinhold2, Hans-Jürgen Smith3
1Department Sensors and Modeling, Leibniz Institute for Agricultural Engineering and Bioeconomy (ATB), Max-Eyth-Allee 100, 14469 Potsdam, Germany.
Abstract:
In the assessment of pulmonary function in health and disease, both respiration rate (RR) and tidal volume (Vt) are fundamental parameters of spontaneous breathing. The aim of this study was to evaluate whether an RR sensor, which was previously developed for cattle, is suitable for additional measurements of Vt in calves. This new method would offer the opportunity to measure Vt continuously in freely moving animals. To measure Vt noninvasively, the application of a Lilly-type pneumotachograph implanted in the impulse oscillometry system (IOS) was used as the gold standard method. For this purpose, we applied both measuring devices in different orders successively, for 2 days on 10 healthy calves. However, the Vt equivalent (RR sensor) could not be converted into a true volume in mL or L. For a reliable recording of the Vt equivalent, a technical revision of the RR sensor excluding artifacts is required. In conclusion, converting the pressure signal of the RR sensor into a flow equivalent, and subsequently into a volume equivalent, by a comprehensive analysis, provides the basis for further improvement of the measuring system.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Volumes and Capacities
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...

