Related Experiment Video
Updated: Jul 23, 2025

Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
Potentiometric-Type Gas Sensor Using MgFe2O4 Sensing Electrode for Detection of Hydrocarbon Based on Carbon Number
Sri Ayu Anggraini1, Yuki Fujio1, Hiroshi Ikeda2
1Sensing System Research Center (SSRC), National Institute of Advanced Industrial Science and Technology (AIST), Tosu, Saga 841-0052, Japan.
Abstract:
Hydrocarbon (HC) monitoring is necessary for safe and effective operations in industries such as petroleum and gas. In this study, total hydrocarbons can be detected by using yttria-stabilized zirconia (YSZ)-based potentiometric-type gas sensor using MgFe2O4 sensing electrode (SE). The sensor was found to generate a similar response magnitude to those of hydrocarbons that have the same carbon number, irrespective of the type of carbon bond (total hydrocarbon detection). Aside from being capable of detecting total hydrocarbons sensitively and selectively with rapid response time, the sensor using MgFe2O4-SE also exhibited a linear relationship between sensor responses and carbon number. In addition to that, the developed sensor showed a logarithmically linear relationship between sensor responses and HC concentration in the range 20-700 ppm. These sensing characteristics were confirmed to be reproducible, and sensor responses toward HC were found to be repeatable and gradually decreased with increasing in O2 concentration in the range of 3-21 vol %.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Potentiometry: Membrane Electrodes
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
High-Performance Liquid Chromatography: Types of Detectors
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...