Related Experiment Video
Updated: Jul 23, 2025

Robotics in Surgery: A Modular Robotic Platform Driven Gastric Wedge Resection
Published on: February 7, 2025
Factors Related to Bleeding and Leak Rates After Robotic Sleeve Gastrectomy
1Department of Surgery, Mount Auburn Hospital, Harvard Medical School, Cambridge, MA, 02138, USA. Rvosburg@mah.harvard.edu.
Background:
Robotic sleeve gastrectomy has been increasing in annual incidence in recent years. Although rare, post op bleeding and leak in these cases can lead to significant morbidity, mortality, and healthcare utilization.
Objectives:
To determine preop comorbidity risk factors and operative techniques associated with risk of bleeding or leak within 30 days of robotic sleeve gastrectomy.
Methods:
The MBSAQIP database was analyzed. A total of 53,548 RSG cases were included in analysis. Surgeries took place from accredited centers in the USA from 2015 to 2019.
Conclusions:
Preoperative anticoagulation, renal failure, COPD, and OSA were found to increase in the risk for transfusion requirements after SG. Receiving a transfusion and smoking increased the risk for leak. Staple line reinforcement significantly decreased transfusion and leak rates. Staple line oversewing did not have an impact on bleeding or leak.
Related Concept Videos
Esophageal Varices-II: Clinical Features and Management
In the initial assessment, a thorough review of the patient's medical history is vital to identify risk factors such as liver disease, alcohol...
Peptic Ulcer Disease V: Surgical Management and Nursing Care
Surgical Interventions for Peptic Ulcer Disease
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...