A smartphone-integrated low-cost, reagent-free, non-destructive dried blood spot-based paper sensor for hematocrit
Smriti Sinha1, Akashlina Basu1, Jai Shukla1
1School of Medical Science and Technology, Indian Institute of Technology, Kharagpur 721302, West Bengal, India. Sou@smst.iitkgp.ac.in.
Abstract:
The blood hematocrit (Hct) level provides vital information about a person's health. Traditional Hct measurement equipment relies heavily on infrastructure and skilled manpower, limiting its broad implementation in resource-limited contexts. Therefore, we developed a simple, reagent-free, non-destructive, smartphone-integrated paper-based device for Hct measurement by analyzing blood-spreading area on a paper substrate. Blood spreading area was found to be dependent on the Hct value, paper properties, and assay duration. This device was calibrated using a custom-made Python algorithm with 10 μl of blood, which produced a sensitivity of -1.90 ± 0.03 mm2/Hct (%) with a LOD as low as 2.17% Hct. The device linear range (8.8 to 58% Hct) is wide enough to cover the clinically relevant range of blood Hct (%). Furthermore, this Python algorithm was coupled with a user-friendly and clinically beneficial Android application (app) to establish an automated tool for quantitative estimation. Comparing the app performance with the result obtained from the gold standard hematology analyzer using blood from 87 subjects reveals a strong correlation (r = 0.99), an average bias of 0.15 with limits of agreement of -2.5 to 2.79 at 95% CI. The device exhibits an accuracy of 96.85% and acceptable reproducibility, with CV ranging from 0.8 to 7.5%. An integrated detection cum readout guiding pattern may allow this device to be suitable for simultaneous quantitative and qualitative estimation and to be employed in both developed and resource-limited clinical settings for Hct measurement in routine checkups and regular monitoring during critical care, as well as in the initial screening of large anemic populations.
More Related Videos
05:18A Rapid and Chemical-free Hemoglobin Assay with Photothermal Angular Light Scattering
Published on: December 7, 2016
09:15Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors
Published on: November 22, 2016