An approach to quantify ortho-phthalaldehyde contamination on work surfaces
Caitlyn A Rogers1, Sharyn E Gaskin1, Leigh D Thredgold1
1Adelaide Exposure Science and Health, School of Public Health, University of Adelaide, Adelaide, South Australia, 5005, Australia.
Abstract:
Ortho-phthalaldehyde (OPA) is used as a high-level disinfectant for reusable medical devices in healthcare settings. The ACGIH recently adopted a Threshold Limit Value-Surface Limit (TLV-SL; 25 µg/100 cm2) for OPA surface contamination to prevent induction of dermal and respiratory sensitization following dermal exposure. However, there is no current validated method to measure OPA surface contamination. This study aimed to develop a standardized approach for sample collection and quantitative determination of OPA from work surfaces for use in risk assessment practices. The reported method utilises readily available commercial wipes to collect surface samples coupled with direct detection of OPA via liquid chromatography time of flight mass spectrometry (LC-ToF-MS). This approach avoided complex derivatization steps commonly required for the analysis of aldehydes. Method evaluation was conducted in accordance with the Occupational Safety and Health Administration (OSHA) surface sampling guidelines. Overall recoveries of 25 µg/100 cm2 of OPA from stainless steel and glass surfaces were 70% and 72%, respectively. The reported LOD for this method was 1.1 µg/sample and the LOQ was 3.7 µg/sample. OPA remained stable on the sampling medium for up to 10 days, when stored at 4 °C. The method was demonstrated in a workplace surface assessment at a local hospital sterilising unit, successfully detecting OPA on work surfaces. This method is intended to supplement airborne exposure assessment and provide a quantitative assessment tool for potential dermal exposure. When used in conjunction with a thorough occupational hygiene program that includes hazard communication, engineering controls, and personal protective equipment, skin exposure and consequent sensitization risks in the workplace can be minimized.
Related Concept Videos
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...