Related Experiment Video
Updated: Jul 23, 2025

An Efficient Method for Selective Desalination of Radioactive Iodine Anions by Using Gold Nanoparticles-Embedded Membrane Filter
Published on: July 13, 2018
Radiological study of a wastewater treatment plant associated with radioiodine therapy at a hospital in West Java,
Tita Dewi Puspita1, Setyo Sarwanto Moersidik1, Mochamad Adhiraga Pratama1
1Environmental Engineering Study Program, Department of Civil Engineering, Universitas Indonesia, Kampus UI Depok, Depok 16424, Indonesia.
Abstract:
Nuclear medicine (NM) services in Indonesia have rapidly developed due to the increasing number of patients, and this growth has been supported by standardized regulations in the field, including the management of solid waste generated. However, multiple reports indicate that licensing control does not regulate liquid waste disposal from patient excretions to protect personnel and the community from radiopharmaceutical exposure. One of the radiopharmaceuticals commonly used in NM and having the longest half-life among the radiopharmaceuticals used in NM is iodine 131(I-131). Thus, this study used a high-purity germanium detector to measure iodine-131 (I-131) activity in liquid waste from decay tanks, temporary collection channels, the hospital's wastewater treatment plant (WWTP) outlet, and six points around the NM service and liquid waste treatment unit. Concentration measurements in three decay tanks were carried out sequentially every 12 h for 3 d, corresponding to the therapy period. The results showed that the I-131 activity levels in the decay tanks and temporary collection channels, before being mixed with liquid waste from other units, were 95.9 × 106± 4.4 × 106Bq m-3.At the point where the liquid waste from other units was mixed, the activity level decreased significantly to 472 680 ± 22 160 Bq m-3, which was below the clearance level of 107Bq m-3. However, the recorded concentration exceeded the standard for environmental radioactivity at the hospital's WWTP outlet, namely 37 670 ± 2040 Bq m-3. The measurement results for I-131 in the air in the open space for two nuclear buildings was above the standard at 1.3 ± 0.27 Bq m-3. According to the RESRAD simulation, based on the initial dose taken from the liquid waste treatment outlet point, the accumulation of doses and the risk of cancer among workers and the community decreased within 3 months after the maximum exposure.
More Related Videos
12:04Fluorescence-Activated Cell Sorting-Radioligand Treated Tissue FACS-RTT to Determine the Cellular Origin of Radioactive Signal
Published on: September 10, 2021
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT