Purpose:
To evaluate the corneal biological parameters stability between the different corneal residual bed thickness (RBT) after Small Incision Lenticule Extraction (SMILE).
Methods:
In this prospective clinical trial, 127 eyes of 64 patients underwent SMILE. According to the corneal RBT, the patients were divided into the 250-270 µm, 270-290 µm and 290-310 µm groups. Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany) and Scheimpflug camera (Pentacam; Oculus Optikgeräte GmbH, Wetzlar, Germany) measurements were performed preoperatively, 1 day, 1week, 1month and 3 months after surgery.
Results:
The keratometer values among the three groups were no significant differences in postoperative periods (each P > 0.05), except the corneal thickness values (each P < 0.05). In the 250-270 µm and 270-290 µm groups, the keratometer and corneal thickness values were decreased at postoperative 1 week and increased at 1 and 3 months. The 290-310 µm group significantly higher posterior maximum elevation (PME) than the 250-270 µm group at 1 and 3 months (P = 0.022, 0.022, respectively), and higher preoperative thinnest point (PTE) at 1 week and 1 month (P = 0.013, 0.035, respectively). The PME of the 290-310 µm group was higher than the 270-290 µm group at 3 months (P = 0.045), and higher PTE at 1 week and 3 months (P = 0.022, 0.02, respectively). In all three groups, the maximal deformation amplitude (DA) was significantly higher at 1 and 3 months compared to postoperative 1 day and 1 week, and the IOP was decreased at 1 month then recovered at 3 months (each P < 0.05).The DA of the 250-270 µm group was significantly higher than the 290-310 µm group at postoperative 1 week, 1 and 3 months (P = 0.001, 0.01, 0.02, respectively). The change of the posterior corneal elevation and biomechanical parameters values were no significant differences among the three groups in postoperative periods (each P > 0.05).
Conclusions:
The range of 250-310 µm RBT was safe and stable at the early postoperative of SMILE. The RBT may be positively correlated with the posterior corneal elevation.