Background:
Individualized positive end-expiratory pressure (PEEP) guided by dynamic compliance improves oxygenation and reduces postoperative atelectasis in nonobese patients. The authors hypothesized that dynamic compliance-guided PEEP could also reduce postoperative atelectasis in patients undergoing bariatric surgery.
Methods:
Patients scheduled to undergo laparoscopic bariatric surgery were eligible. Dynamic compliance-guided PEEP titration was conducted in all patients using a downward approach. A recruitment maneuver (PEEP from 10 to 25 cm H2O at 5-cm H2O step every 30 s, with 15-cm H2O driving pressure) was conducted both before and after the titration. Patients were then randomized (1:1) to undergo surgery under dynamic compliance-guided PEEP (PEEP with highest dynamic compliance plus 2 cm H2O) or PEEP of 8 cm H2O. The primary outcome was postoperative atelectasis, as assessed with computed tomography at 60 to 90 min after extubation, and expressed as percentage to total lung tissue volume. Secondary outcomes included Pao2/inspiratory oxygen fraction (Fio2) and postoperative pulmonary complications.
Results:
Forty patients (mean ± SD; 28 ± 7 yr of age; 25 females; average body mass index, 41.0 ± 4.7 kg/m2) were enrolled. Median PEEP with highest dynamic compliance during titration was 15 cm H2O (interquartile range, 13 to 17; range, 8 to 19) in the entire sample of 40 patients. The primary outcome of postoperative atelectasis (available in 19 patients in each group) was 13.1 ± 5.3% and 9.5 ± 4.3% in the PEEP of 8 cm H2O and dynamic compliance-guided PEEP groups, respectively (intergroup difference, 3.7%; 95% CI, 0.5 to 6.8%; P = 0.025). Pao2/Fio2 at 1 h after pneumoperitoneum was higher in the dynamic compliance-guided PEEP group (397 vs. 337 mmHg; group difference, 60; 95% CI, 9 to 111; P = 0.017) but did not differ between the two groups 30 min after extubation (359 vs. 375 mmHg; group difference, -17; 95% CI, -53 to 21; P = 0.183). The incidence of postoperative pulmonary complications was 4 of 20 in both groups.
Conclusions:
Postoperative atelectasis was lower in patients undergoing laparoscopic bariatric surgery under dynamic compliance-guided PEEP versus PEEP of 8 cm H2O. Postoperative Pao2/Fio2 did not differ between the two groups.
More Related Videos
09:31Normothermic Negative Pressure Ventilation Ex Situ Lung Perfusion: Evaluation of Lung Function and Metabolism
Published on: February 14, 2022
05:39Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Pneumonia V: Nursing management and Prevention
The nurse must practice strict medical asepsis and adhere to infection control guidelines to minimize healthcare-associated infections.
Enhance airway patency
Position the patient correctly to facilitate drainage of the affected lung segments. Manual or mechanical percussion and vibration can also be employed....
Mechanical Ventilation I: Indication and Settings
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...