Related Experiment Video
Updated: Jul 23, 2025

Author Spotlight: Learning Systematic Bronchoscopy in a Simulation-Base Setting
Published on: June 23, 2023
Optimal Duration of High-Fidelity Simulator Training for Bronchoscope-Guided Intubation: A Noninferiority Randomized
Luyang Jiang1, Qingmei Yang, Qingyue Li
1From the Department of Anesthesiology (L.J., Q.L., B.J., Y.F.), Peking University People's Hospital, Beijing, China; and Department of Anesthesiology (Q.Y., B.J., C.L.), Tibet Autonomous Region People's Hospital, Lhasa, Tibet, China.
Introduction:
The optimal simulator training duration for flexible optical bronchoscopic (FOB) intubation is unknown. This study aimed to determine whether a learning curve-based training modality was noninferior to a fixed training time modality in terms of clinical FOB intubation time.
Methods:
This multicenter, randomized, noninferiority study was conducted from May to August 2022. Anesthesiology residents or interns were enrolled. Eligible participants were randomized in a 1:1 ratio to receive new learning curve-based simulator training (individualized training time based on performance, group New) or reference fixed training time simulator training (1 hour, group Reference). The primary outcome was the time to complete FOB intubation in patients, which was defined as the time from the introduction of the FOB into the mouth until the first capnography visualization. The margin for detecting clinical significance was defined as 10 seconds.
Results:
A total of 32 participants were included in the analysis (16 in each group). All trainees successfully intubated the patients. The mean intubation time (95% confidence interval [CI]) was 81.9 (65.7-98.1) seconds in group New and 97.0 (77.4-116.6) seconds in group Reference. The upper bound of the 1-sided 97.5% CI for the mean difference of clinical intubation time between groups was 9.3 seconds. Noninferiority was claimed. The mean duration of the training in group New was 28.4 (95% CI, 23.5-33.4) minutes. The total number of training procedures on simulators in group New was significantly less than that in group Reference ( P < 0.01).
Conclusions:
The clinical FOB intubation time in group New was noninferior to that in group Reference.
More Related Videos
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...