Related Experiment Video
Updated: Jun 26, 2026

Fabrication And Characterization Of Photonic Crystal Slow Light Waveguides And Cavities
Published on: November 30, 2012
Configurable circular-polarization-dependent optoelectronic silent state for ultrahigh light ellipticity
Yonghao Bu1,2, Xiansong Ren1,3, Jing Zhou4,5
1State Key Laboratory of Infrared Physics, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, 500 Yu Tian Road, 200083, Shanghai, China.
Abstract:
Filterless light-ellipticity-sensitive optoelectronic response generally has low discrimination, thus severely hindering the development of monolithic polarization detectors. Here, we achieve a breakthrough based on a configurable circular-polarization-dependent optoelectronic silent state created by the superposition of two photoresponses with enantiomerically opposite ellipticity dependences. The zero photocurrent and the significantly suppressed noise of the optoelectronic silent state singularly enhance the circular polarization extinction ratio (CPER) and the sensitivity to light ellipticity perturbation. The CPER of our device approaches infinity by the traditional definition. The newly established CPER taking noise into account is 3-4 orders of magnitude higher than those of ordinary integrated circular polarization detectors, and it remains high in an expanded wavelength range. The noise equivalent light ellipticity difference goes below 0.009° Hz-1/2 at modulation frequencies above 1000 Hz by a light power of 281 μW. This scheme brings a leap in developing monolithic ultracompact circular polarization detectors.
More Related Videos
14:18Automation of Mode Locking in a Nonlinear Polarization Rotation Fiber Laser through Output Polarization Measurements
Published on: February 28, 2016
00:07A Photonic System for Generating Unconditional Polarization-Entangled Photons Based on Multiple Quantum Interference
Published on: September 5, 2019
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
High-Performance Liquid Chromatography: Types of Detectors