Related Experiment Video
Updated: Jul 23, 2025

Translational Orthotopic Models of Glioblastoma Multiforme
Published on: February 17, 2023
Evaluation of RANO Criteria for the Assessment of Tumor Progression for Lower-Grade Gliomas
Fabio Raman1,2, Alexander Mullen2, Matthew Byrd3
1Department of Radiology, Johns Hopkins Hospital, 600 N Wolfe St., Baltimore, MD 21287, USA.
Purpose:
The Response Assessment in Neuro-Oncology (RANO) criteria for lower-grade gliomas (LGGs) define tumor progression as ≥25% change in the T2/FLAIR signal area based on an operator's discretion of the perpendicular diameter of the largest tumor cross-section. Potential sources of error include acquisition inconsistency of 2D slices, operator selection variabilities in both representative tumor cross-section and measurement line locations, and the inability to quantify infiltrative tumor margins and satellite lesions. Our goal was to assess the accuracy and reproducibility of RANO in LG.
Materials And Methods:
A total of 651 FLAIR MRIs from 63 participants with LGGs were retrospectively analyzed by three blinded attending physicians and three blinded resident trainees using RANO criteria, 2D visual assessment, and computer-assisted 3D volumetric assessment.
Results:
RANO product measurements had poor-to-moderate inter-operator reproducibility (r2 = 0.28-0.82; coefficient of variance (CV) = 44-110%; mean percent difference (diff) = 0.4-46.8%) and moderate-to-excellent intra-operator reproducibility (r2 = 0.71-0.88; CV = 31-58%; diff = 0.3-23.9%). When compared to 2D visual ground truth, the accuracy of RANO compared to previous and baseline scans was 66.7% and 65.1%, with an area under the ROC curve (AUC) of 0.67 and 0.66, respectively. When comparing to volumetric ground truth, the accuracy of RANO compared to previous and baseline scans was 21.0% and 56.5%, with an AUC of 0.39 and 0.55, respectively. The median time delay at diagnosis was greater for false negative cases than for false positive cases for the RANO assessment compared to previous (2.05 > 0.50 years, p = 0.003) and baseline scans (1.08 > 0.50 years, p = 0.02).
Conclusion:
RANO-based assessment of LGGs has moderate reproducibility and poor accuracy when compared to either visual or volumetric ground truths.
More Related Videos
06:32Evaluation of Biomarkers in Glioma by Immunohistochemistry on Paraffin-Embedded 3D Glioma Neurosphere Cultures
Published on: January 9, 2019
09:09Laser Capture Microdissection of Glioma Subregions for Spatial and Molecular Characterization of Intratumoral Heterogeneity, Oncostreams, and Invasion
Published on: April 12, 2020