Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Assessing the Novel Myval Balloon-Expandable Valve with the Evolut Valve: A Propensity-Matched Study
Jonathan Halim1, Maxim Rooijakkers2, Peter den Heijer1
1Department of Cardiology, Amphia Hospital Breda, Molengracht 21, 4818 CK Breda, The Netherlands.
Background:
The Myval balloon-expandable (BE) valve has shown encouraging early clinical data in terms of safety and efficacy. Comparative data with other well-established contemporary valves are nonetheless still scarce. This study aims to compare the performance of the Myval BE valve with the Evolut self-expanding (SE) valve.
Methods:
In this retrospective single-center study, 223 patients with symptomatic severe aortic stenosis (AS) were included and treated with the Myval BE valve (n = 120) or with the Evolut SE valve (n = 103). Then, 91 pairs were compared after matching. Clinical outcomes were evaluated at 30 days and 1 year. Echocardiographic follow-up was performed at 30 days.
Results:
Procedural complications were rare in both groups. At the 30-day follow-up, no significant difference in cardiac death (Myval: 1% vs. Evolut: 2%, p = 0.56), stroke (2% vs. 4%, p = 0.41) and myocardial infarction (1% vs. 3%, p = 0.31) was observed. A permanent pacemaker implantation (PPI) was significantly less needed in the Myval group (4% vs. 15%, p = 0.01). At 1 year, cardiac death (2% vs. 4%, p = 0.41) and the stroke rate (7% vs. 5%, p = 0.76) were similar. Moderate-severe paravalvular leakage (PVL) was also comparable in both groups (1% vs. 4%, p = 0.17).
Conclusion:
Safety and efficacy outcomes were comparable between the two valves, except for a higher PPI rate for the Evolut SE valve. Up to 1-year follow-up, clinical outcomes showed acceptable rates of stroke and cardiac death with both valves. Valve hemodynamics were excellent with a low rate of moderate-severe PVL in both groups.
Related Concept Videos
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse I: Introduction
Mitral Stenosis III: Medical Management
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Stenosis I: Introduction
Mitral Regurgitation III: Medical Management