Abstract:
Sample handling is still a weak point in chromatography and in analytical chemistry in general. One consideration is the automation potential of new procedures. Solid-liquid extraction techniques in combination with pre-column technology are particularly promising in this regards. The construction and geometry of pre-columns both for conventional and narrow-bore HPLC are of major importance, since band broadening should be kept at a minimum for an optimal functioning of the analytical system. The various operations that can be carried out with such a pre-column are trace-enrichment, clean-up of the sample which depends on the type of adsorbents used in the precolumn, i.e., polar or apolar materials, ion exchangers or metal covered surfaces, etc., protection of the analytical column, field sampling and storage of samples and as a substrate for on-column chemical derivatizations. These various operations are demonstrated with practical examples from the fields of environmental and biological analysis. The selectivity can be further enhanced by coupling pre-column technology with selective detection models such as diode array UV, electrochemical or fluorescence detection. This enables the construction of optimal and integrated analysis systems which are fully automated and microprocessor controlled. They can also be made compatible with miniaturized LC-technology.
More Related Videos
11:25Multi-step Preparation Technique to Recover Multiple Metabolite Compound Classes for In-depth and Informative Metabolomic Analysis
Published on: July 11, 2014
09:09Preparation of Human Tissues Embedded in Optimal Cutting Temperature Compound for Mass Spectrometry Analysis
Published on: April 27, 2021
Related Concept Videos
Principles Of Column Chromatography
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
Sample Handling
Samples should be transported carefully from collection points to the laboratory. They should be properly sealed and clearly labeled to prevent cross-contamination. To preserve the sample integrity, optimal temperature conditions during transport are essential. This could involve using...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
High-Performance Liquid Chromatography: Elution Process