Related Experiment Video
Updated: Aug 5, 2026

13:37
Polymer Microarrays for High Throughput Discovery of Biomaterials
Published on: January 25, 2012
14.6K
A Polymer-Based Indicator for Detecting Dexamethasone in Herbal Medicine Using Polymethylmethacrylate (PMMA)
Rimadani Pratiwi1, Vandie Charlie1, Nyi Mekar Saptarini1
1Department of Pharmaceutical Analysis and Medicinal Chemistry, Faculty of Pharmacy, Universitas Padjadjran, Bandung 45363, Indonesia.
Polymers
|July 14, 2023
Summary
A new polymer-based indicator can quickly detect the banned drug dexamethasone in herbal medicines. This simple test offers a reliable alternative to complex lab analysis for ensuring herbal product safety.
Area of Science:
- Analytical Chemistry
- Polymer Science
- Pharmacology
Background:
- Dexamethasone is often illicitly added to herbal medicines for its anti-inflammatory and pain-relief properties.
- Uncontrolled consumption of dexamethasone in herbal products can lead to severe adverse side effects.
- Current methods for detecting dexamethasone in herbal samples are often complex and time-consuming.
Purpose of the Study:
- To develop a simple, fast, and cost-effective polymer-based indicator for detecting dexamethasone in herbal medicine.
- To assess the selectivity, sensitivity, and stability of the developed indicator strips.
- To validate the indicator strips' performance using real-world herbal samples.
Main Methods:
- Indicator strips were fabricated by blending polymethylmethacrylate (PMMA) polymer with sulfuric acid (H2SO4).
- The method involved a colorimetric reaction where H2SO4 reacts with dexamethasone to produce a distinct pink-purple color.
- The developed indicator strips were tested against various herbal samples, and results were compared with Thin-Layer Chromatography (TLC) and High-Performance Liquid Chromatography (HPLC).
Main Results:
- The polymer-based indicator strips selectively detected dexamethasone, producing a visible color change.
- The detection limit for dexamethasone was found to be as low as 13.13 ppm.
- The indicator strips demonstrated good stability for up to 36 days and accurately identified dexamethasone in 5 out of 9 tested herbal samples, consistent with TLC and HPLC results.
Conclusions:
- The developed polymer-based indicator strips offer a simple, rapid, and applicable method for on-site detection of dexamethasone in herbal medicines.
- This novel indicator provides a valuable tool for quality control and regulatory agencies to ensure the safety of herbal products.
- The findings highlight the potential of polymer-based indicators for the on-site screening of adulterated traditional medicines.
Related Concept Videos
Qualitative Analysis
For solutions containing mixtures of different cations, the identity of each cation can be determined by qualitative analysis. This technique involves a series of selective precipitations with different chemical reagents, each reaction producing a characteristic precipitate for a specific group of cations. Metal ions within a group are further separated by varying the pH, heating the mixture to redissolve a precipitate, or adding other reagents to form complex ions.
For instance, group IV...
For instance, group IV...
Gas Chromatography: Types of Detectors-II
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
Fineness Modulus
The fineness modulus (FM) of aggregate is a numerical index that measures the coarseness or fineness of the particles. It is calculated by adding the cumulative percentages of aggregate retained on each of a specified series of sieves and dividing the sum by 100.
Consider performing sieve analysis on sand through a set of ASTM sieves. The weight of aggregate retained in each sieve and pan placed at the bottom is recorded, as given in Column B of Table 1.
To determine the fineness modulus of...
Consider performing sieve analysis on sand through a set of ASTM sieves. The weight of aggregate retained in each sieve and pan placed at the bottom is recorded, as given in Column B of Table 1.
To determine the fineness modulus of...