Related Experiment Video
Updated: Jul 23, 2025

Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
Signal Quality Analysis of Single-Arm Electrocardiography
Jia-Jung Wang1, Shing-Hong Liu2, Cheng-Hsien Tsai1
1Department of Biomedical Engineering, I-Shou University, Kaohsiung 84001, Taiwan.
Abstract:
The number of people experiencing mental stress or emotional dysfunction has increased since the onset of the COVID-19 pandemic, as many individuals have had to adapt their daily lives. Numerous studies have demonstrated that mental health disorders can pose a risk for certain diseases, and they are also closely associated with the problem of mental workload. Now, wearable devices and mobile health applications are being utilized to monitor and assess individuals' mental health conditions on a daily basis using heart rate variability (HRV), typically measured by the R-to-R wave interval (RRI) of an electrocardiogram (ECG). However, portable or wearable ECG devices generally require two electrodes to perform bipolar limb leads, such as the Einthoven triangle. This study aims to develop a single-arm ECG measurement method, with lead I ECG serving as the gold standard. We conducted static and dynamic experiments to analyze the morphological performance and signal-to-noise ratio (SNR) of the single-arm ECG. Three morphological features were defined, RRI, the duration of the QRS complex wave, and the amplitude of the R wave. Thirty subjects participated in this study. The results indicated that RRI exhibited the highest cross-correlation (R = 0.9942) between the single-arm ECG and lead I ECG, while the duration of the QRS complex wave showed the weakest cross-correlation (R = 0.2201). The best SNR obtained was 26.1 ± 5.9 dB during the resting experiment, whereas the worst SNR was 12.5 ± 5.1 dB during the raising and lowering of the arm along the z-axis. This single-arm ECG measurement method offers easier operation compared to traditional ECG measurement techniques, making it applicable for HRV measurement and the detection of an irregular RRI.
More Related Videos
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Dysrhythmias V: Evaluating Dysrhythmias
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...

