Related Experiment Video
Updated: Jul 23, 2025

05:30
Large Scale Energy Efficient Sensor Network Routing Using a Quantum Processor Unit
Published on: September 8, 2023
605
Efficient Cluster Tree Topology Operation and Routing for IEEE 802.15.4-Based Smart Grid Networks
Jin-Woo Kim1, Jaehee Kim1, Jaeho Lee2
1Department of Statistics, Duksung Women's University, Seoul 01369, Republic of Korea.
Sensors (Basel, Switzerland)
|July 14, 2023
Summary
A new multi-channel cluster tree protocol enhances wireless sensor networks for smart grids. It reduces data collisions and end-to-end delay, improving quality of service (QoS) for critical applications.
Area of Science:
- Computer Science
- Electrical Engineering
- Network Engineering
Background:
- Wireless Sensor Networks (WSNs) are crucial for smart grid communication.
- WSNs must handle delay-critical data and limited resources for Quality of Service (QoS).
- Existing protocols like IEEE 802.15.4 MAC face challenges in meeting smart grid demands.
Purpose of the Study:
- To propose a novel multi-channel cluster tree protocol for WSNs in smart grid applications.
- To enhance network performance by minimizing collisions and end-to-end delay.
- To ensure long-term QoS provisioning within the constraints of WSN resources.
Main Methods:
- A multi-channel cluster tree protocol is designed.
- Cluster heads broadcast beacon frames with channel and time slot information.
- New nodes use this information to self-configure their communication parameters.
Main Results:
- The proposed protocol effectively prevents data collisions.
- Achieved significantly lower end-to-end delay compared to IEEE 802.15.4 MAC.
- Demonstrated improved network performance for smart grid applications.
Conclusions:
- The multi-channel cluster tree protocol offers a superior solution for smart grid WSNs.
- It meets the stringent QoS requirements for delay-critical data transmission.
- The protocol efficiently utilizes network resources for enhanced performance.
Related Concept Videos
Fast Decoupled and DC Powerflow
239
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
239
Transmission Line Design Considerations
171
Aluminum has become the material of choice for overhead transmission lines, surpassing copper due to its abundance and cost-effectiveness. The most prevalent type is the aluminum conductor, steel-reinforced (ACSR), which combines aluminum strands around a steel core. Other variants include all-aluminum conductors (AAC), all-aluminum alloy conductors (AAAC), aluminum conductor alloy-reinforced (ACAR), and aluminum-clad steel conductors. Advanced designs, such as aluminum conductors with steel...
171
Maximum Power Flow and Line Loadability
138
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
138
Power System Distribution
269
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
269
Primary Distribution
127
Primary distribution systems deliver electrical power from substations to consumers through various voltage classes, with 15-kV class voltages being predominant among U.S. utilities. Older 2.5- and 5-kV classes are being replaced by 15-kV primaries, while higher 25- to 34.5-kV classes are used in high-density urban areas and rural regions with long feeders. Three-phase, four-wire multigrounded systems are widely employed for balanced power delivery, using the neutral wire as a grounding point.
127
Secondary Distribution
108
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
108