Related Experiment Video
Updated: Jun 24, 2026

An Inertial Measurement Unit Based Method to Estimate Hip and Knee Joint Kinematics in Team Sport Athletes on the Field
Published on: May 26, 2020
The Effects of a Simple Sensor Reorientation Procedure on Peak Tibial Accelerations during Running and Correlations
Molly M Bradach1, Logan W Gaudette1, Adam S Tenforde1
1Spaulding National Running Center, Department of Physical Medicine and Rehabilitation, Harvard Medical School, Cambridge, MA 02138, USA.
Abstract:
While some studies have found strong correlations between peak tibial accelerations (TAs) and early stance ground reaction forces (GRFs) during running, others have reported inconsistent results. One potential explanation for this is the lack of a standard orientation for the sensors used to collect TAs. Therefore, our aim was to test the effects of an established sensor reorientation method on peak Tas and their correlations with GRFs. Twenty-eight runners had TA and GRF data collected while they ran at a self-selected speed on an instrumented treadmill. Tibial accelerations were reoriented to a body-fixed frame using a simple calibration trial involving quiet standing and kicking. The results showed significant differences between raw and reoriented peak TAs (p < 0.01) for all directions except for the posterior (p = 0.48). The medial and lateral peaks were higher (+0.9-1.3 g), while the vertical and anterior were lower (-0.5-1.6 g) for reoriented vs. raw accelerations. Correlations with GRF measures were generally higher for reoriented TAs, although these differences were fairly small (Δr2 = 0.04-0.07) except for lateral peaks (Δr2 = 0.18). While contingent on the position of the IMU on the tibia used in our study, our results first showed systematic differences between reoriented and raw peak accelerations. However, we did not find major improvements in correlations with GRF measures for the reorientation method. This method may still hold promise for further investigation and development, given that consistent increases in correlations were found.
Related Concept Videos
Measuring Acceleration Due to Gravity
A simple pendulum can be described as a point mass and a string. Meanwhile, a physical pendulum is any object whose oscillations are similar to a simple pendulum, but cannot be modeled as a point mass on a string because its mass is distributed over a larger area. The behavior of a physical pendulum can be modeled using the principles of...
Root-Locus Method
This system can be represented by a block diagram,...
Distance Corrections
Application of Linearization and Approximation

