Related Experiment Video
Updated: Aug 17, 2026

A Bedside, Single Burr Hole Approach to Multimodality Monitoring in Severe Brain Injury
Published on: March 26, 2019
Utility of Bedside Ultrasound Measurement of Optic Nerve Sheath Diameter as a Screening Tool for raised Intracranial
Sushma Gurav1, Kapil Zirpe2, Abhaya Bhoyar3
1Consultant; Corresponding Author.
Abstract:
Intracranial pressure (ICP) needs to be monitored in neurocritical patients. There is a need for portable bedside optic nerve ultrasound (ONUS) for early diagnosis to initiate the measures to reduce ICP Objective: To find the utility of bedside ONUS to diagnose raised ICP in neurocritical care. Materials and methods: After approval from the ethical committee, a prospective observational study was conducted. Optic nerve sheath diameter (ONSD) was measured in two groups: control group patients with neurological symptoms but computed tomography (CT)/magnetic resonance imaging (MRI) not suggestive of raised ICP, and second was study group patients with neurological symptoms and CT/MRI suggestive of elevated ICP Result: In patients with normal ICP, the mean ONSD in females was 4.47mm, and in males was 4.66mm. In patients with raised ICP, the mean ONSD in females was 6.45 ± 0.78 mm, and in males was 6.33 ± 0.70 mm. Regarding the correlation between Glasgow coma scale (GCS) and mean ONSD parameters, the coefficient of correlation (R) is 0.14; thus, there is a weak negative correlation. In our study, no difference was observed in raised mean ONSD in patients with different diagnoses. At a cut-off value of >4.8 mm, the sensitivity and specificity are 100% to diagnose raised ICP. Conclusion: Optic nerve sheath diameter (ONSD) is a reliable, rapid bedside screening tool in the Emergency Department/Critical Care/Operation Theatre to diagnose raised ICP. In order to keep a record of trends in ICP, we need to measure ONSD frequently. There was no correlation between GCS and ONSD measurement.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure