A Simple Approach to Perform TEER Measurements Using a Self-Made Volt-Amperemeter with Programmable Output Frequency
Published on: October 5, 2019
Modification of transformer coupled permeameter for frequency extension.
1Reserach Center for Emerging Computing Technologies (RCECT), National Institute of Advanced Industrial Science and Technology (AIST), Central 2, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568, Japan.
The transformer coupled permeameter (TC-Perm) was enhanced to measure magnetic material permeability from 1 MHz to 44 GHz. This extended range is crucial for developing advanced noise suppression materials for 5G mmWave applications.
Area of Science:
- Electromagnetics and Materials Science
- Advanced Measurement Techniques
Background:
- Previous transformer coupled permeameter (TC-Perm) system operated from 10 MHz to 20 GHz.
- High-frequency limitations were due to unwanted mode excitation around 22 GHz.
- Low-frequency limitations were caused by high noise figures (NF) of the vector network analyzer input.
Purpose of the Study:
- To modify the TC-Perm system to extend its operational frequency range.
- To improve high-frequency performance by suppressing unwanted modes.
- To enhance low-frequency sensitivity by reducing the system's noise figure.
Main Methods:
- Modified jig design with a ground plane and vias to suppress unwanted modes.
- Incorporated a low noise amplifier and analog switches to reduce system noise figure.
- Tested the modified system's transmission characteristics and noise performance.
Main Results:
- Extended the high-frequency limit to 44 GHz with clean transmission characteristics.
- Reduced the noise figure to 2.7 dB below 100 MHz.
- Achieved a broadband operation range of 1 MHz to 44 GHz.
Conclusions:
- The modified TC-Perm system offers significantly extended broadband frequency coverage.
- The enhanced system is suitable for characterizing magnetic materials for 5G mmWave noise suppression.
- The improvements enable more comprehensive material analysis for advanced wireless communication technologies.
Related Concept Videos
Instrument Transformers
Transformers with Off-Nominal Turns Ratios
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
The Ideal Transformer
Ampere's Law forms the basis of understanding the magnetic field within the transformer. It states that the integral of the magnetic field intensity's...
Transformers
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...
Properties of Fourier Transform I
In radio broadcasting, multiple audio signals often need to be transmitted simultaneously. The Fourier...