Related Experiment Video
Updated: Jul 23, 2025

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
CT and chest radiography in evaluation of mechanical circulatory support devices for acute heart failure
Abhishek Chaturvedi1, Yonatan Rotman2, Timothy Hoang2
1Department of Imaging Science, Cardiothoracic Imaging, University of Rochester Medical Center, 601 Elmwood Ave, Rochester, NY, 14562, USA. toabhic@gmail.com.
Abstract:
Acute heart failure and cardiogenic shock are a major cause of morbidity and mortality in patients who have had recent cardiac surgery, myocardial infarct or pulmonary hypertension. The use of percutaneous mechanical circulatory support (MCS) devices before organ failure occurs can improve outcomes in these patients. Imaging plays a key role in identifying appropriate positioning of MCS devices for supporting ventricle function. These devices can be used for left ventricle, right ventricle or biventricular support. Fluoroscopy, angiography and echocardiography are used for implanting these devices. Radiographs and CT can identify both intra- and extra-cardiac complications. The cardiothoracic imager will see increasing use of these devices and familiarity with their normal appearance and complications is important. CRITICAL RELEVANCE STATEMENT: Chest radiographs and CT are useful for assessing the position of the mechanical cardiac support device used for treatment of acute heart failure. CT can identify cardiac and extra-cardiac complications associated with these devices. KEY POINTS: IABP upper/distal marker should be 2-3 cm distal to the ostia of the left subclavian artery. Inlet of Impella CP should be 3.5 cm below the aortic valve. The Impella 5.5 does not have a pigtail portion. The inlet should be about 5 cm below the aortic annulus. Impella RP inlet port should be in the right atrium or inferior vena cava, the pigtail portion should be positioned in the main pulmonary artery. Protek Duo inflow is in the right atrium or right ventricle. The outflow is in the main pulmonary artery.
More Related Videos
06:29Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
Published on: June 11, 2019
09:05Assessment of Cardiac Morphological and Functional Changes in Mouse Model of Transverse Aortic Constriction by Echocardiographic Imaging
Published on: June 21, 2016
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Mitral Stenosis II: Clinical features and Diagnostic Tests
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Radiological Investigation I: X-ray and CT