Related Experiment Video
Updated: Jul 23, 2025

Quantifying Mixing using Magnetic Resonance Imaging
Published on: January 25, 2012
Hierarchical K-means clustering method for accelerated Lorentzian estimation (KALE) in chemical exchange saturation
Yanrong Chen1, Yaozong Sun1, Chongxue Bie1
1School of Information Sciences and Technology, Northwest University, Xi'an, China.
Background:
Quantification of in vivo chemical exchange saturation transfer (CEST) magnetic resonance signals is challenging due to contamination from coexisting effects, including the direct water effect and asymmetric magnetization transfer. Fitting-based analysis allows the calculation of multiple types of signals from the line shape of Z-spectra. However, the conventional voxelwise method has several drawbacks, including its long computation time and its susceptibility to image noise and Z-spectra oscillations, and it is difficult to determine the initial fitting parameters.
Methods:
Herein, we propose a K-means clustering method for accelerated Lorentzian estimation (KALE) in CEST quantification. Briefly, voxels in CEST images are clustered into K groups according to their Z-spectra characteristics. A 'groupwise' fitting process is then performed with preset initial values, yielding a set of fitted spectra and fitted parameters for each group. With the updated initial values, each group is further clustered into subgroups, and groupwise fitting is performed again. This hierarchical K-means clustering and parameter updating process continues until the pixel number or intensity error meets the termination criteria. Voxelwise fitting could be further conducted to improve the quantification images (termed voxel-K) by utilizing the previous groupwise KALE results as the initial values (termed group-K).
Results:
Incorporated with Lorentzian difference (LD) quantification, KALE was first optimized and evaluated on 5 healthy human brain datasets at 3 Tesla. Compared with traditional voxel-by-voxel LD quantification, the computation times of group-K and voxel-K were significantly reduced by ~85% and ~70%, respectively (P<0.001). Furthermore, the group-K images exhibited better denoising performance than traditional LD and voxel-K. KALE was further validated on six ischemic rat brains acquired at 7 Tesla, with both LD_group-K and LD_voxel-K displaying almost identical contrast maps with traditional voxelwise maps. When incorporated with the five-pool Lorentzian fitting (LF), KALE exhibited an improved contrast-to-noise ratio (CNR) for amplitude maps of each pool [P=0.003, 0.015, 0.047, and 0.047 for amide, nuclear Overhauser effect (NOE), magnetic transfer (MT) and guanidine amine, respectively] and improved fitting goodness (P=0.033).
Conclusions:
KALE quantification provides comparable or even superior contrast maps to traditional voxelwise fitting, with significantly reduced computation time. The 'smart' and hierarchical voxel-clustering and parameter updating process of KALE may facilitate more preclinical and clinical CEST applications.
More Related Videos
Related Concept Videos
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
2D NMR: Overview of Heteronuclear Correlation Techniques
NMR Spectrometers: Resolution and Error Correction
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation
On...