Related Experiment Video
Updated: Jul 29, 2026

Handheld Metal Detector Screening for Metallic Foreign Body Ingestion in Children
Published on: September 11, 2018
Fluoroscopy-Guided Metallic Foreign Body Removal: A Report of Three Cases and Literature Review
Thamer M AlBilasi1, Lama F AlDhawi2, Ahmed N AlOlaywi3
1Department of Otolaryngology - Head and Neck Surgery, Prince Sultan Military Medical City, Riyadh, SAU.
Abstract:
Ingested foreign objects that become trapped in the upper aerodigestive tract is a common issue that arises in Otolaryngology-Head and Neck Surgery practice. In these circumstances, it is advised to explore the neck using an external method to remove the item. However, locating the foreign body might be challenging. Not all metallic foreign body (MFB) patients require surgery, especially those without symptoms or complications. The standard X-ray and CT images are routinely examined for preoperative assessment and localization. Removal can be accomplished via flexible pharyngo-laryngoscopy or upper gastrointestinal endoscopy. Fluoroscopy is a widely accessible, minimally invasive, but underutilized tool during procedures. It offers an accurate intraoperative assessment of the foreign body in real-time. To allow the planning of a secure extraction pathway, the target should be radiopaque. In this report, we present three unique cases in which we used fluoroscopic imaging for guidance to remove a foreign body in the head and neck region in Prince Sultan Military Medical City in Riyadh, Saudi Arabia. In the first case, a young male presented with a history of foreign body sensation and odynophagia in the throat after eating a (shawarma) sandwich. In the second case, a six-year-old boy presented to the emergency department (ED) with epistaxis after being exposed to an air gun shot to his face. In the third case, a 40- year-old male presented after exposure to an air gun shot to the neck. After identification of the foreign body, all three patients were referred to Otolaryngology-Head and Neck. After radiological images have been done to confirm the presence of foreign objects, all three had a minimally invasive procedure to remove the metallic foreign bodies under fluoroscopic guidance without needing extensive surgery. All the procedures went well with no immediate complications with discharge on the same day. Fluoroscopy-guided removal of foreign bodies related to metabolic forging is a promising technique with several advantages, including real-time visualization, reduced invasiveness, and shorter recovery times. However, it is essential to weigh the benefits against the risks associated with radiation exposure and inherent limitations in detecting non-metallic objects. Further research and clinical studies are needed to optimize this technique and establish evidence-based guidelines for its application in the field of metabolic forging bodies.
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Extraction: Advanced Methods