Background:
This study aimed to assess the accuracy of digital workflow for guided insertion of miniscrews in the anterior palate using restorative implant dentistry software and licensed software for orthodontic applications.
Methods:
Twenty subjects (8 males, 12 females, mean age = 16.7 ± 2.1 years) were prospectively selected to receive guided insertion of bicortical palatal miniscrews. Virtual planning was performed using restorative implant dentistry software (Blue Sky Plan*, version 4.7) (group 1 = 10 subjects) and licensed orthodontic software (Dolphin Imaging Software, version 11.0) (group 2 = 10 subjects). A specific 3D Imaging technology was applied to permit the registration of the planned and achieved position of the miniscrews based on the superimposition of maxillary models. The angular deviation (accuracy error) between the planned and the achieved positions of the miniscrews were recorded. Independent Student's test was used with statistical significance set at p value < 0.05.
Results:
The mean accuracy error recorded in group 1 was 7.15° ± 1.09 (right side) and 6.19 ± 0.80 (left side) while the mean error in group 2 was 6.74° ± 1.23 (right side) and 5.79 ± 0.95 (left side). No significant differences were recorded between the two groups (p > 0.05); instead, miniscrews placed on the right side were almost one degree higher than the left side (p < 0.05) in both groups.
Conclusions:
The clinical accuracy error was similar when using generic and licensed orthodontic software for guided systems.