Better flexion and early recovery with medial-stabilized vs single-radius total knee arthroplasty with kinematic alignment: Two-year clinical results
Related Experiment Video
Updated: Jul 23, 2025

In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
Brett K Jones1, Brian J Carlson1, David F Scott2
1Elson S. Floyd College of Medicine Washington State University, 412 E Spokane Falls Blvd, Spokane, WA 99202, USA.
Background:
There are few studies comparing outcomes in patients with posterior cruciate ligament-sacrificing single-radius (SR) versus medial-stabilized (MS) knee devices. Both types of implants are designed to maximize deep-flexion and to maintain stability throughout the knee flexion arc. The aim of this study was to determine whether two-year outcomes differ between these two implant groups.
Methods:
Two-hundred and ten patients took part in this retrospective cohort single center study. The SR patients (n = 109) were enrolled in one randomized trial, and the MS knees (n = 101) in another. Patient consent and Investigative Review Board approval was obtained. Radiographs and clinical outcomes were gathered preoperatively and at six weeks, six months, one year and two years.
Results:
There were no statistically significant differences between treatment groups in terms of preoperative demographic characteristics. The MS group had significantly better knee flexion starting at six months postoperative through two years postoperatively (p < 0.05 - p< 0.001). The Knee Society Pain/Motion score was better in the MS group at one year (95.41 vs 90.86, p < 0.002). The Knee Society Pain score was also better in the MS group starting at six weeks through one year (six weeks: 35.3 vs 30, p = 0.007; one year: 46.4 vs 42.4, p = 0.005, respectively).
Conclusion:
The MS group had better clinical outcomes than the SR group, with significantly greater knee flexion from six months through two years, better Knee Society Pain scores at six weeks through one year, and higher Knee Society Pain/Motion scores at six weeks and one year postoperatively.