Related Experiment Video
Updated: Jul 27, 2026

Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
Comparison of major spine navigation platforms based on key performance metrics: a meta-analysis of 16,040 screws
John-Peter Bonello1, Robert Koucheki2,3, Aazad Abbas2
1Temerty Faculty of Medicine, University of Toronto, 1 King's College Circle, Toronto, ON, M5S 1A8, Canada. jp.bonello@mail.utoronto.ca.
Purpose:
The objective of this meta-analysis is to compare available computer-assisted navigation platforms by key performance metrics including pedicle screw placement accuracy, operative time, neurological complications, and blood loss.
Methods:
A systematic review was conducted using major databases for articles comparing pedicle screw accuracy of computer-assisted navigation to conventional (freehand or fluoroscopy) controls via post-operative computed tomography. Outcome data were extracted and pooled by random-effects model for analysis.
Results:
All navigation platforms demonstrated significant reduction in risk of breach, with Stryker demonstrating the highest accuracy compared to controls (OR 0.16 95% CI 0.06 to 0.41, P < 0.00001, I2 = 0%) followed by Medtronic. There were no significant differences in accuracy or most surgical outcome measures between platforms; however, BrainLab demonstrated significantly faster operative time compared to Medtronic by 30 min (95% CI - 63.27 to - 2.47, P = 0.03, I2 = 74%). Together, there was significantly lower risk of major breach in the navigation group compared to controls (OR 0.42, 95% CI 0.27-0.63, P < 0.0001, I2 = 56%).
Conclusions:
When comparing between platforms, Stryker demonstrated the highest accuracy, and Brainlab the shortest operative time, both followed by Medtronic. No significant difference was found between platforms regarding neurologic complications or blood loss. Overall, our results demonstrated a 60% reduction in risk of major breach utilizing computer-assisted navigation, coinciding with previous studies, and supporting its validity. This study is the first to directly compare available navigation platforms offering insight for further investigation and aiding in the institutional procurement of platforms. LEVEL 3 EVIDENCE: Meta-analysis of Level 3 studies.
Related Concept Videos
Design of Prismatic Beams for Bending
Method of Superposition
When applying the method of superposition, each type of load—whether...
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
Euler's Formula for Pin-Ended Columns
To calculate the critical load, envision...
Euler's Formula to Columns with Other End Conditions
Euler's Formula to Columns: Problem Solving
The system comprises two vertical rigid bars, AB and BC, of...

