Related Experiment Video
Updated: Jul 22, 2025

Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
Pressure-controlled versus manual facemask ventilation for anaesthetic induction in adults: A randomised controlled
Lennart Edmark1,2, Emma-Karin Englund1, Alexandra Schöttle Jonsson1
1Department of Anaesthesia and Intensive Care, Västmanland Hospital Köping, Köping, Sweden.
Background:
Pressure-controlled face mask ventilation (PC-FMV) with positive end-expiratory pressure (PEEP) after apnoea following induction of general anaesthesia prolongs safe apnoea time and reduces atelectasis formation. However, depending on the set inspiratory pressure, a delayed confirmation of a patent airway might occur. We hypothesised that by lowering the peak inspiratory pressure (PIP) when using PC-FMV with PEEP, confirmation of a patent airway would not be delayed as studied by the first return of CO2 , compared with manual face mask ventilation (Manual FMV).
Methods:
This was a single-centre, randomised controlled non-inferiority trial. Seventy adult patients scheduled for elective day-case surgery under general anaesthesia with body mass index between 18.5 and 29.9 kg m-2 , American Society of Anesthesiologists (ASA) classes I-III, and without anticipated difficult FMV, were included. Before the start of pre-oxygenation and induction of general anaesthesia, participants were randomly allocated to receive ventilation with either PC-FMV with PEEP, at a PIP of 11 and a PEEP of 6 cmH2 O or Manual FMV, with the adjustable pressure-limiting valve set at 11 cmH2 O. The primary outcome variable was the number of ventilatory attempts needed until confirmation of a patent airway, defined as the return of at least 1.3 kPa CO2 .
Results:
The return of ≥1.3 kPa CO2 on the capnography curve was observed after mean ± SD, 3.6 ± 4.2 and 2.5 ± 1.9 ventilatory attempts/breaths with PC-FMV with PEEP and Manual FMV, respectively. The difference in means (1.1 ventilatory attempts/breaths) had a 99% CI of -1.0 to 3.1, within the accepted upper margin of four breaths for non-inferiority.
Conclusion:
Following induction of general anaesthesia, PC-FMV with PEEP was used without delaying a patent airway as confirmed with capnography, if moderate pressures were used.
More Related Videos
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:

