Design, manufacturing, and testing of 0.35/25 kV, 20 kHz transformers for particle accelerators
Aritra Chakraborty1,2, Paul D Christian1, Amal S1
1Institute for Plasma Research, Bhat Village, Near Indira Bridge, Gandhinagar 382428, India.
Abstract:
A high voltage, high frequency transformer unit has been designed and built for powering the Cockcroft-Walton voltage multiplier to be used as part of a particle accelerator power supply at the Institute For Plasma Research, India, for the nuclear fusion research facility. A novel combination of high voltage (25 kV), high frequency (20 kHz), and high power (70 kV A) specifications makes its design distinctive and more challenging. The complete unit is composed of two 0.350/25 kV amorphous core transformers connected in center-tap configuration and immersed in an oil-filled tank. To facilitate an iterative design procedure, a spreadsheet method was utilized. The design involved a methodical approach for the core and winding selection, followed by the magnetic analysis and high voltage insulation layout through the finite element method. All the magnetic, electrical, and thermal parameters have been evaluated in detail, assuring a continuous stable operation having an efficiency of greater than 95%. Finally, the transformers were made, and preliminary experiments, including turns ratio, short-circuit, and dielectric tests, were carried out to verify the accuracy of the proposed design. The unit was also field tested under actual load conditions, and the test results were presented and corroborated with the design calculations.
More Related Videos
08:31Sample Preparation and Experimental Design for In Situ Multi-Beam Transmission Electron Microscopy Irradiation Experiments
Published on: June 27, 2022
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Related Concept Videos
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Nuclear Transmutation
Instrument Transformers
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
Van de Graaff Generator
Van de Graaff uses both smooth and pointed surfaces, conductors, and insulators to generate large static charges and, hence, large voltages. A substantial excess charge can be deposited on the sphere because it moves...