Problem Solving MRI to Reduce False-Positive Biopsy Related to Breast US: Conductivity vs. DWI vs. Abbreviated
Jun-Hyeong Kim1, Soo-Yeon Kim2,3,4, Chuanjiang Cui1
1Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea.
Conductivity imaging showed potential in reducing false-positive breast biopsies but performed less effectively than diffusion-weighted imaging (DWI) and abbreviated MRI. These advanced imaging techniques offer improved accuracy for breast mass diagnosis.
Area of Science:
- Radiology
- Medical Imaging
- Oncology
Background:
- Breast ultrasound (US) is valuable for diagnosing breast masses but can lead to false-positive biopsies due to overlapping features and subjective interpretation.
- Differentiating benign from malignant breast lesions remains a challenge, necessitating advanced diagnostic tools.
Purpose of the Study:
- To assess the efficacy of conductivity imaging in reducing false-positive biopsy results for breast masses.
- To compare the performance of conductivity imaging against diffusion-weighted imaging (DWI) and abbreviated MRI.
Main Methods:
- A prospective study involving 79 women with 86 BI-RADS category 4 breast masses detected by US.
- Evaluated conductivity imaging, DWI, and abbreviated MRI by measuring conductivity parameters, apparent diffusion coefficient (ADC) values, and BI-RADS categories.
- US-guided biopsy served as the reference standard.
Main Results:
- US-guided biopsy identified 65 benign and 21 malignant lesions.
- Conductivity imaging (AUC=0.74) reduced false-positive biopsies by 23%.
- Diffusion-weighted imaging (ADC) reduced false-positives by 38%, and abbreviated MRI by 43%, without missing malignant lesions.
Conclusions:
- Conductivity imaging may have lower performance in reducing unnecessary breast biopsies compared to DWI and abbreviated MRI.
- DWI and abbreviated MRI demonstrate superior potential in improving diagnostic accuracy and minimizing false-positive biopsy results.
More Related Videos
06:08A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
Published on: March 21, 2025
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Related Concept Videos
Magnetic Resonance Imaging
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...