Related Experiment Video
Updated: Jul 22, 2025

Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
Non-contact heart vibration measurement using computer vision-based seismocardiography
Mohammad Muntasir Rahman1, Jadyn Cook1, Amirtahà Taebi2
1Department of Agricultural and Biological Engineering, Mississippi State University, Mississippi, 39762, USA.
Abstract:
Seismocardiography (SCG) is the noninvasive measurement of local vibrations of the chest wall produced by the mechanical activity of the heart and has shown promise in providing clinical information for certain cardiovascular diseases including heart failure and ischemia. Conventionally, SCG signals are recorded by placing an accelerometer on the chest. In this paper, we propose a novel contactless SCG measurement method to extract them from chest videos recorded by a smartphone. Our pipeline consists of computer vision methods including the Lucas-Kanade template tracking to track an artificial target attached to the chest, and then estimate the SCG signals from the tracked displacements. We evaluated our pipeline on 14 healthy subjects by comparing the vision-based SCG[Formula: see text] estimations with the gold-standard SCG[Formula: see text] measured simultaneously using accelerometers attached to the chest. The similarity between SCG[Formula: see text] and SCG[Formula: see text] was measured in the time and frequency domains using the Pearson correlation coefficient, a similarity index based on dynamic time warping (DTW), and wavelet coherence. The average DTW-based similarity index between the signals was 0.94 and 0.95 in the right-to-left and head-to-foot directions, respectively. Furthermore, SCG[Formula: see text] signals were utilized to estimate the heart rate, and these results were compared to the gold-standard heart rate obtained from ECG signals. The findings indicated a good agreement between the estimated heart rate values and the gold-standard measurements (bias = 0.649 beats/min). In conclusion, this work shows promise in developing a low-cost and widely available method for remote monitoring of cardiovascular activity using smartphone videos.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System IV: CMRI

