Atrial mechanical contraction and ambulatory atrioventricular synchrony: Predictors from the OPTIVALL study
Sem Briongos-Figuero1, Álvaro Estévez Paniagua1, Ana Sánchez Hernández1
1Cardiology Department, Infanta Leonor Hospital, Madrid, Spain.
Introduction:
The role that preprocedural factors have on atrioventricular synchrony (AVS) provided by leadless pacemakers requires investigation.
Methods And Results:
We aimed to assess the correlation between mitral inflow echocardiographic parameters and p-wave morphology with the accelerometer A4 signal amplitude. We also sought to identify clinical and echocardiographic predictors of optimal ambulatory AVS (≥85% of cardiac cycles). Forty-three patients undergoing Micra AV implant from June 2020 to March 2023 were prospectively enrolled. Baseline echocardiogram and 12-lead resting ECG were performed. Device follow-up was scheduled at 24 h, 1, 3, and 6 months and yearly after the implant. Ambulatory AVS was studied with a 24 h Holter monitor performed at 3 months follow-up in 35 patients who remained in VDD mode. A4 signal amplitude at 1 month correlated to peak A wave velocity (r = .376; p = .024) at echocardiogram, but no relationship was found with peak A' wave velocity, E/A, or E'/A' ratio. P-wave amplitude in lead I and aVF correlated to A4 signal amplitude at 1- and 3-months follow-up, respectively. Median AVS during 24 h of daily activities was 85.6 ± 7.6% and remained stable up to 100 bpm. Twenty-three out of 35 patients (65.7%) reached optimal ambulatory AVS. There was no association between mitral inflow echocardiographic parameters and optimal AVS. Diabetes (OR: 0.05, 95% CI: 0.01-0.47; p = .009) and chronic obstructive pulmonary disease (COPD) (OR: 0.06, 95% CI: 0.01-0.63; p = .019) strongly predicted ambulatory AVS <85%.
Conclusions:
Diabetes and COPD should be considered when selecting candidates for Micra AV. Measurements of pulsed wave Doppler mitral inflow do not systematically reflect the behavior of the A4 signal amplitude.
More Related Videos
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
08:05Optimization of Transesophageal Atrial Pacing to Assess Atrial Fibrillation Susceptibility in Mice
Published on: June 29, 2022
Related Concept Videos
Mechanism of Cardiac Arrhythmias
Electrophysiology of Normal Cardiac Rhythm
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation