Related Experiment Video
Updated: Jul 22, 2025

Invasive Hemodynamic Characterization of the Portal-hypertensive Syndrome in Cirrhotic Rats
Published on: August 1, 2018
Analysis of transjugular intrahepatic portosystemic shunt by hemodynamic simulation
Junjie Cao1, Zhichao Yao1, Guijun Huo1
1Department of Vascular Surgery, Gusu School of Nanjing Medical University, Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital (HQ), Suzhou, China.
Background:
Transjugular intrahepatic portosystemic shunt (TIPS), which artificially creates a portocaval shunt to reduce portal venous pressure, has gradually become the primary treatment for portal hypertension (PH). However, there is no prefect shunting scheme in TIPS to balance the occurrence of postoperative complications and effective haemostasis.
Objective:
To construct cirrhotic PH models and compare different shunting schemes in TIPS.
Methods:
Three cases of cirrhotic PH with different liver volumes were selected for enhanced computed tomography scanning. The models for different shunting schemes were created using Mimics software, and following FLUENT calculation, all the models were imported into the software computational fluid dynamic-post for processing. In each shunting scheme, the differences in portal vein pressure, hepatic blood perfusion and blood flow from the superior mesenteric vein in the shunt tract were compared. The coefficient G was adapted to evaluate the advantages and disadvantages.
Results:
(1) Concerning the precise location of the shunt tract, the wider the diameter of the shunt tract, the lower the pressure of the portal vein and the lesser the hepatic blood perfusion. Meanwhile, the pressure drop objective was not achieved with the 6 mm-diameter shunting scheme. (2) The 8 mm-diameter shunting scheme through the left portal vein (LPV) had the highest coefficient G.
Conclusion:
The 8 mm-diameter shunting scheme through the LPV may demonstrate a superior effect and prognosis in TIPS procedures.
Related Concept Videos
Hepatic Portal System
At its core, the hepatic portal vein is the result of a confluence of the superior and inferior mesenteric veins along with the splenic vein. Each of these veins has a unique role. The superior mesenteric vein is...
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models