Related Experiment Video
Updated: Jul 22, 2025

Multicolor Fluorescence Detection for Droplet Microfluidics Using Optical Fibers
Published on: May 5, 2016
Fluorescence detection of three types of pollutants based on fluorescence resonance energy transfer and its
Yifei Kong1, Dan Liu1, Xinran Guo1
1School of Pharmacy, Lanzhou University Lanzhou 730000 P. R. China chenxinyue888@126.com +86-15293109642.
Abstract:
This study aimed at three representative pollutants, benzidine, cyromazine, and streptomycin, which were commonly used and posed a great threat to both environment and human health, mainly to explore a fast, simple, sensitive, visible naked-eye detection method. Colorimetric detection by gold nanoparticles (AuNPs) was first attempted. The cross-linking reaction occurred owing to the strong forces between the targets and AuNPs, leading to aggregation and color change. However, large-scale aggregation was easily formed and settled, which failed to achieve accurate quantification. Thus, AuNPs are considered to be used in fluorescence detection as reaction bridges. The introduction of AuNPs could effectively quench the fluorescence of Rhodamine B based on fluorescence resonance energy transfer (FRET). Moreover, a classical "on-off-on" fluorescence detection system was constructed based on nanomaterials. When AuNPs were added, the red fluorescence of the Rhodamine B solution could be effectively quenched (the "off" reaction). However, the tight cross-linking reaction between the three targets and AuNPs occurred through the strong affinity, causing Rhodamine B to dissociate in the solution. The fluorescence was rapidly restored, accompanied by a significant enhancement of fluorescence intensity (the "on" reaction). The fluorescent responses toward the three targets were established, resulting in good linearity in a wide range with low detection limits. Moreover, through the investigation of specificity, the fluorescence sensor exhibited satisfying selectivity and high binding affinity to the detected targets among the same types of inferences, indicating great potential for practical application. This simple, fast and sensitive fluorescence detection system was first used for simultaneously detecting three types of pollutants and finally successfully applied to real samples.
Related Concept Videos
Photoluminescence: Applications
Fluorescence and Phosphorescence: Instrumentation
Gas Chromatography: Types of Detectors-II
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Immunofluorescence Microscopy
Super-resolution Fluorescence Microscopy