Related Experiment Video
Updated: Jul 22, 2025

Subcostal Specimen Removal in Completely Portal Robotic Lobectomy
Published on: April 19, 2024
Transthoracic robotic plication for diaphragmatic elevation
Merve Şengül İnan1, Kuthan Kavaklı1, Hakan Işık1
1Department of Thoracic Surgery, Gülhane Training and Research Hospital, Ankara, Türkiye.
Background:
This study aims to evaluate the feasibility, safety, and efficacy of transthoracic robot-assisted surgery for diaphragmatic plication and to describe our surgical approach in detail.
Methods:
Between January 2014 and January 2020, a total of 13 patients (11 males, 2 females; median age: 55 years; range, 24 to 70 years) who underwent diaphragmatic plication with the robotic system were retrospectively analyzed. The changes in the Medical Research Council dyspnea scale, forced expiratory volume in 1 sec, body mass index, and quality of life scale scores of the patients before the operation and at the first year of follow-up were examined.
Results:
Twelve of the operations were performed on the left side. The median pre- and postoperative Medical Research Council dyspnea scores were 2 (range, 1 to 4) and 1 (range, 1 to 4), respectively, indicating a statistically significant improvement (p=0.008). A significant improvement was detected in the forced expiratory volume in 1 sec of the patients in the first year after surgery (p=0.036). In terms of quality of life parameters, only, in the physical health subscale, the scores were statistically significantly different in the pre- and postoperative first-year follow-up (p=0.002). Median time to chest tube removal was 1 (range 1-5, IQR=0,5) days. Median total length of hospital stay was 2 (range 2-18, IQR=3) days.
Conclusion:
Owing to its technical dexterity, the robot enables the plication to be performed easily and safely. Late improvement in respiratory functions is reflected in quality of life.