Related Experiment Video
Updated: Jul 22, 2025

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
Artificial intelligence-based computer-assisted detection/diagnosis (AI-CAD) for screening mammography: Outcomes of
Jung Hyun Yoon1, Kyungwha Han2, Hee Jung Suh3
1Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Center for Clinical Imaging Data Science, Yonsei University, College of Medicine, South Korea.
Purpose:
To evaluate the stand-alone diagnostic performances of AI-CAD and outcomes of AI-CAD detected abnormalities when applied to the mammographic interpretation workflow.
Methods:
From January 2016 to December 2017, 6499 screening mammograms of 5228 women were collected from a single screening facility. Historic reads of three radiologists were used as radiologist interpretation. A commercially-available AI-CAD was used for analysis. One radiologist not involved in interpretation had retrospectively reviewed the abnormality features and assessed the significance (negligible vs. need recall) of the AI-CAD marks. Ground truth in terms of cancer, benign or absence of abnormality was confirmed according to histopathologic diagnosis or negative results on the next-round screen.
Results:
Of the 6499 mammograms, 6282 (96.7%) were in the negative, 189 (2.9%) were in the benign, and 28 (0.4%) were in the cancer group. AI-CAD detected 5 (17.9%, 5 of 28) of the 9 cancers that were intially interpreted as negative. Of the 648 AI-CAD recalls, 89.0% (577 of 648) were marks seen on examinations in the negative group, and 267 (41.2%) of the AI-CAD marks were considered to be negligible. Stand-alone AI-CAD has significantly higher recall rates (10.0% vs. 3.4%, P < 0.001) with comparable sensitivity and cancer detection rates (P = 0.086 and 0.102, respectively) when compared to the radiologists' interpretation.
Conclusion:
AI-CAD detected 17.9% additional cancers on screening mammography that were initially overlooked by the radiologists. In spite of the additional cancer detection, AI-CAD had significantly higher recall rates in the clinical workflow, in which 89.0% of AI-CAD marks are on negative mammograms.