Non-channeled Video Laryngoscopy as an Alternative to Conventional Laryngoscopy for Intubating Adult Patients in the
Aparna Shukla1, Ravi Shanker1, Vipin K Singh1
1Anaesthesiology, King George's Medical University, Lucknow, IND.
Abstract:
Background Endotracheal intubation in the intensive care unit (ICU) is often a risky procedure due to the emergency situation, unstable condition of the patient, and technical problems such as inadequate positioning. Several new techniques, such as video laryngoscopy, have been developed recently to improve the success rate of first-pass intubations and reduce complications. We conducted this study to compare a non-channeled reusable video laryngoscope BPL VL-02 (manufactured by BPL Medical Technologies, Bangalore, India) with a conventional laryngoscope for intubation of adult patients in the ICU. Methodology A total of 72 ICU patients were randomly allocated to be intubated with either conventional direct laryngoscopy via Macintosh blade (group A) or video laryngoscopy with BPL VL-02 (group B). All patients were intubated by the primary investigator and the assistant noted the following parameters: the total number of intubation attempts, total duration of intubation, assistance or alternative technique required, Cormack Lehane grading, and any complications. Results There was no significant difference in the Cormack Lehane grading, number of attempts, or complications between the two groups. On comparing the assistance required during intubation in patients, it was observed that four (11.11%) patients in group A and seven (19.44%) patients in group B needed backward, upward, and rightward pressure on the larynx assistance during intubation. In five (13.89%) patients in group B, Stylet was required during intubation. The difference was statistically significant (p = 0.0308). The video laryngoscopy group (group B) had a longer mean duration of intubation (64.36 ± 6.28 seconds) compared to group A (45.72 ± 11.45 seconds), and the difference was statistically significant (p < 0.0001). Conclusions Non-channeled video laryngoscope (BPL VL-02) is not a suitable alternative to conventional direct laryngoscopy with a Macintosh blade in terms of successful first-pass intubation, total duration of intubation, and assistance required.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Cardiopulmonary Resuscitation II: ACLS Airway Management
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...