Related Experiment Video For Anemia
Updated: Jul 22, 2025

Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Anemia detection and quantification in contrast-enhanced CT scans on a novel photon-counting detector CT: A
Josua A Decker1, Adrian Huber1, Fevzi Senel1
1Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Stenglinstr. 2, 86156 Augsburg, Germany.
Purpose:
To correlate CT values of the blood pool on VNC series with serum hemoglobin values for the detection of anemia in oncologic patients undergoing contrast-enhanced PCD-CT scans.
Methods:
This prospective study (NCT04989192) included consecutive oncologic patients undergoing contrast-enhanced CT on a novel PCD-CT system between 08/2021 and 01/2022. The interval between complete blood count (CBC) and CT scan acquisition had to be no more than seven days. CT-values of the blood pool were measured on 70 keV VMI series (CT-values(BP)70keV) and on VNC series (CT-values(BP)VNC) at five anatomic positions (left atrium, left ventricle, main pulmonary artery, ascending and descending aorta) and averaged per patient. Pearson correlation analyses and ROC analyses were performed to identify relations between CT-values(BP)VNC, CBC parameters, and degrees of anemia as defined by the WHO (no anemia, mild, moderate, severe anemia).
Results:
A total of 329 patients (age 68 ± 12 years; 200 men) were included. CT-values(BP)VNC showed a strong linear correlation to serum hemoglobin (r2 = 0.80, p <.001) and hematocrit (r2 = 0.76, p <.001) and were significantly different between anemia subgroups in both women and men (ΔHU: 3.5-11.4; all p <.01). ROC analyses yielded high diagnostic performance for the identification of patients without anemia, patients without and with mild anemia, and patients with severe anemia using gender-specific cutoffs for CT-value(BP)VNC (all AUC's > 0.90).
Conclusions:
The spectral information inherent in PCD-CT acquisitions allows the detection and quantification of anemia in contrast-enhanced CT acquisitions of oncologic patients with high diagnostic accuracy.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...